Single Seal - Flushing Water Piping
In order for the Single Seal to work well, it must charge the stuffing
box chamber properly. The outlet piping is gauged to monitor the
internal pressure, paired with a throttling valve to increase or
decrease the desired seal pressure.
Double Seal - Flushing Water Piping
The Double Seal is designed to control the internal stuffing box
chamber pressure.
Cold flushing water is used to disperse heat generated within the
two internal sealing stages and a gauge is placed at the discharge
port to properly and easily monitor internal pressure during the
seal's life span.
After the monitoring gauge is installed, a throttling gauge is put
in place to allow the mill to increase or decrease seal pressure.
Now, the venturi throttling valve is installed. This valve remains
open during start-up and allows internal venturi heat to escape.
The venturi valve will remain empty until seal failure occurs. When
this happens, it will receive excess flushing water, not allowing
it to escape.
Now, even though seal failure has occurred, the pump can be scheduled
for repairs at a later and more convenient time.
|